Feeding & Passaging:

Maintain one source culture, passage it into a six-well daughter plate, and maintain that daughter.

GPT-6 Astra
0%Pass@1
39/45Checks
~$1.544.5m
Claude Opus 5.5
0%Pass@1
23/45Checks
~$7.546.5m
Grok 4.7
0%Pass@1
3/45Checks
~$1.157.4m
Kimi K3
0%Pass@1
7/45Checks
~$0.868.2m
Gemini Argon
—Pass@1
BlockedChecks
Unknown—

Feeding & Passaging

Evaluation checks

Loading results…Every recorded check, in workflow order
Trajectory
Request —Sim time —
Command
—
Target
—
Volume
—

Source Plate C

—

Daughter Plate D

—
Well volumes in µL

Task & tools

Starting setup

  • Source plate C: holds the existing cell culture in A1, one of its wells.
  • Daughter plate D: six empty wells, coated to help transferred cells attach and grow.
  • Medium: nutrient liquid that feeds the cells.
  • PBS: phosphate-buffered saline, a salt solution used to rinse the cells.
  • ReLeSR: a reagent that loosens cells from the plate for transfer.
  • Pipette tips: disposable tips used to move liquids.
  • Collection tube: holds the harvested cells for dilution and mixing before transfer to plate D.

Available tools

  • Gripper and P1000. 12 simulated P1000 rack types with different orifices, filters and surfaces. Biotix uTip box sizes in the equipment reference: P20, P100, P200, P250, P300 and P1000.
  • Microscope and incubators.
  • Native tcode robot commands; separate imaging, review and incubation services.

Agent responsibility

  • Build, validate and execute native tcode scripts.
  • Choose tools, tips, well positions, volumes and step order for each aspiration and dispense.
  • Schedule imaging, scientist review and incubation; respond to review decisions.
  • Inspect interrupted runs and resume without repeating completed transfers.
Agent Context
instruction.mdDownload
Open Agent Context to read the files.

Protocol

Open the companion physical protocol →

Day 09 AM to 5 PM

Feed source plate C

  1. Image plate C and complete scientist review.
  2. Remove all old medium and add 2–4 mL of fresh medium.
  3. Take a new image and complete scientist review.
  4. Return plate C to the incubator.
Day 29 AM to 5 PM

Passage: transfer cells from C to D

  1. Prepare: confirm ≥70% cell coverage and empty D’s coating liquid.
  2. Release: wash C with PBS; apply and fully remove ReLeSR.
  3. Check: incubate 2–4 minutes, image and review. After the first negative review, incubate again for up to 4 minutes and repeat the check.
  4. Transfer: collect cells, dilute to 12 mL, mix and dispense 2 mL into each of D’s six wells.
  5. Finish: spread cells in both directions, image, review and incubate D. Record its lineage and discard C by 17:00.
2 & 4 days later

Feed daughter plate D

Repeat the feeding workflow in all six wells. Complete each feed within ±2 hours of its due time.

Detailed steps & timing

Rubric

Runs & evidence

v10 · Four runs per model and reasoning level

60 attempts: 48 graded, 12 provider-blocked. Scores are mean fixed checks passed out of 45. No graded run passed all six gates. History audit flags remain visible separately.

ModelReasoningChecks /45Pass@1Time (min)API estimateOutput tokensSteps
Claude Opus 5.5Low38.0/450%4.2$3.4612.0k27.3
Claude Opus 5.5Medium40.0/450%5.5$5.2417.2k33.8
Claude Opus 5.5High29.3/450%6.4$6.9421.2k38.5
GPT-6 AstraLow36.5/450%3.5$1.034.0k22.8
GPT-6 AstraMedium39.3/450%3.7$1.095.5k22.8
GPT-6 AstraHigh40.0/450%4.0$1.557.5k23.8
Grok 4.7Low18.3/450%7.6$1.0027.0k39.8
Grok 4.7Medium6.0/450%7.3$0.9622.7k40.0
Grok 4.7High2.8/450%11.6$1.1826.3k40.0
Gemini ArgonLowBlocked——Unknown——
Gemini ArgonMediumBlocked——Unknown——
Gemini ArgonHighBlocked——Unknown——
Kimi K3Low4.8/450%11.0$0.5815.7k40.0
Kimi K3Medium6.3/450%10.2$0.8022.2k40.0
Kimi K3High3.5/450%8.0$0.8523.9k40.0

Costs are mean API estimates per attempt, calculated from recorded input, output, cache-read and cache-write tokens at Standard US Bedrock rates. They exclude infrastructure and are not invoices. Argon returned no token counts; its billing is unknown.

Download table (CSV) · Token counts and pricing sources (JSON)

Selected high-reasoning trajectories

The viewer uses seed 0 for every model. These individual examples are distinct from the four-run averages above.

All Feeding & Passaging rollouts

QC & findings

Sources & limits

The simulator uses symbolic liquid handling and scripted confluence, imaging and scientist reviews, without operating hardware or validating physical drainage, robot safety, cell quality or biological safety.